California Contractors License Law and Reference BookContractors' State License Board, 1957 |
From inside the book
Results 1-3 of 47
Page 210
... ceiling , the minimum ceil- ing height is required in only one - half its area . However , the clear ceiling height shall not be less than three feet in every portion of the room inclosure , and the cubic air content of the room shall ...
... ceiling , the minimum ceil- ing height is required in only one - half its area . However , the clear ceiling height shall not be less than three feet in every portion of the room inclosure , and the cubic air content of the room shall ...
Page 245
... Ceiling masonry not less than three inches thick . A - H 17704.1 . Any portion of any apartment house or hotel ... ceiling of such area Ceiling shall be not less fire resistive than a double ceiling of metal lath A — H only , each ...
... Ceiling masonry not less than three inches thick . A - H 17704.1 . Any portion of any apartment house or hotel ... ceiling of such area Ceiling shall be not less fire resistive than a double ceiling of metal lath A — H only , each ...
Page 294
... ceiling on metal or wire lath gypsum or portland cement plaster ** / Slab 3 Concrete or gypsum slab 2 % 2 % 24 2 Ceiling , gypsum plaster 2 11 3⁄4 // Steel joist or light steel construction , with at- tached or suspended ceil- ing of ...
... ceiling on metal or wire lath gypsum or portland cement plaster ** / Slab 3 Concrete or gypsum slab 2 % 2 % 24 2 Ceiling , gypsum plaster 2 11 3⁄4 // Steel joist or light steel construction , with at- tached or suspended ceil- ing of ...
Contents
C2A23 | 6 |
Types of Questions | 12 |
Business and Professions Code Sections 116 and 162 | 34 |
11 other sections not shown
Other editions - View all
Common terms and phrases
action affidavit Amendment filed apartment house appliances applicable to buildings approved August 17 awarding body Berkeley bond chapter claim of lien claimant classification compensation insurance concrete construction contractor whose principal deed of trust division dwelling employee enforcement agency examination filed for record fire door fire escape fire-resistive fixtures floor area furnished guest room gypsum hearing house or hotel inches injury inner court installed ister joists labor less license materials metal lath minimum misdemeanor NOTE-Is applicable notice occupancy officer thereof owner paid party payment penalty permit person plaster prescribed principal contracting business proposed decision public hallway pursuant rear yard registrar renewal Retroactive section roof Safety Orders section number skill to intelligently specialty contractor specifications square feet stairway stories in height structure subcontractor subdivision surety tion UNIVERSITY OF CALIFORNIA unless vent shaft ventilation violation wages walls water-closet width window